Capsule Filling Machine air pressure is a common systemic problem, that is, vacuum negative pressure can separate the capsule body from the capsule cap after capsule seeding.


capsule filling machine factory


Therefore, before using the capsule filling machine, it is necessary to check whether the air pressure system of the machine is normal and whether the power is enough.


Then it is necessary to check each station of the capsule filling machine, such as capsule separation mechanism, capsule turntable, powder filling device can be synchronized;


In addition, there are some factors that may affect the normal work of the automatic capsule filling machine.


For example, the capsule does not fall smoothly, and the reason may be that the capsule size is too large or there is foreign body blockage.


At this time, it is necessary to replace qualified capsules or change the matching mold, and remove debris with tools.


automatic capsule machine service


In addition, the operator should pay attention to capsule body falling capsule can not correctly into capsule plate hole in this kind of situation, this may be because the capsule filling machine, mold positioning deviation, untight seal or vacuum tubes, or the vacuum pump power is too low, at his time,we can adjust the mould or clean the filter and replace more powerful vacuum pump.